{"id":12540,"date":"2026-06-16T15:38:11","date_gmt":"2026-06-16T07:38:11","guid":{"rendered":"https:\/\/www.skzindustrial.com\/?p=12540"},"modified":"2026-06-22T15:40:06","modified_gmt":"2026-06-22T07:40:06","slug":"stop-guessing-start-titrating-with-confidence-the-skz-ti-50-does-the-heavy-lifting-for-you","status":"publish","type":"post","link":"https:\/\/www.skzindustrial.com\/zh\/stop-guessing-start-titrating-with-confidence-the-skz-ti-50-does-the-heavy-lifting-for-you\/","title":{"rendered":"Stop guessing, start titrating with confidence \u2013 the SKZ Ti-50 does the heavy lifting for you."},"content":{"rendered":"<p class=\"ds-markdown-paragraph\"><span class=\"\">Let\u2019s be real \u2013 manual titration is tedious, error\u2011prone, and eats up your afternoon. \ud83d\ude29<\/span><br \/>\n<span class=\"\">You watch the colour change, count drops, pray your eyes don\u2019t deceive you\u2026 and then re\u2011do it all because the R\u00b2 isn\u2019t good enough.<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">That\u2019s exactly why we built the\u00a0<\/span><strong><span class=\"\">Ti\u201150 (641021C11)<\/span><\/strong><span class=\"\">\u00a0\u2013 an\u00a0<\/span><strong><span class=\"\">automatic potentiometric titrator<\/span><\/strong><span class=\"\">\u00a0that turns hours of sweat into minutes of clean, GLP\u2011compliant data.<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">What\u2019s under the hood?<\/span><\/strong><br \/>\n<span class=\"\">\ud83d\udcf1\u00a0<\/span><strong><span class=\"\">Full\u2011touch screen<\/span><\/strong><span class=\"\">\u00a0\u2013 no cryptic buttons, just tap and go<\/span><br \/>\n<span class=\"\">\ud83e\udde0\u00a0<\/span><strong><span class=\"\">100 built\u2011in titration methods<\/span><\/strong><span class=\"\">\u00a0\u2013 plus you can edit, copy, and create your own<\/span><br \/>\n<span class=\"\">\ud83d\udcca\u00a0<\/span><strong><span class=\"\">200 GLP result sets + 200 titration curves<\/span><\/strong><span class=\"\">\u00a0\u2013 stored right on board, ready for audit or PC export<\/span><br \/>\n<span class=\"\">\ud83d\udda8\ufe0f\u00a0<\/span><strong><span class=\"\">Printer &amp; PC connectivity<\/span><\/strong><span class=\"\">\u00a0\u2013 because paper trails matter<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Specs that speak for themselves:<\/span><\/strong><br \/>\n<span class=\"\">\u26a1 pH: 0.000 ~ 20.000 | mV: \u00b12000.00 | Temp: \u20135.0 ~ 105.0 \u00b0C<\/span><br \/>\n<span class=\"\">\ud83c\udfaf\u00a0<\/span><strong><span class=\"\">Repeatability \u2264 0.2%<\/span><\/strong><span class=\"\">\u00a0\u2013 that\u2019s the kind of precision that makes your QC manager smile<\/span><br \/>\n<span class=\"\">\ud83d\udca7 Burette accuracy: 10 mL \u00b10.020 mL \/ 20 mL \u00b10.030 mL \u2013 certified grade<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">But here\u2019s the real magic \u2013 it handles almost every titration type you throw at it:<\/span><\/strong><br \/>\n<span class=\"\">\u2705 Pre\u2011titration (dynamic), endpoint, blank, constant, manual<\/span><br \/>\n<span class=\"\">\u2705 Acid\u2011base, redox, precipitation, complexation,\u00a0<\/span><strong><span class=\"\">and non\u2011aqueous<\/span><\/strong><span class=\"\">\u00a0\u2013 yes, even the tricky ones<\/span><br \/>\n<span class=\"\">\u2705 Direct pH measurement as a bonus<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">And we didn\u2019t make you hunt for accessories \u2013 the full kit is included:<\/span><\/strong><br \/>\n<span class=\"\">\ud83d\udd39 10 mL burette assembly<\/span><br \/>\n<span class=\"\">\ud83d\udd39 Reference electrodes (232\u201101, 217\u201101)<\/span><br \/>\n<span class=\"\">\ud83d\udd39 Pt electrode (213\u201101), Ag electrode (216\u201101)<\/span><br \/>\n<span class=\"\">\ud83d\udd39 pH glass electrode (231\u201101)<\/span><br \/>\n<span class=\"\">\ud83d\udd39 Temperature probe T\u2011818\u2011B\u20116<\/span><br \/>\n<span class=\"\">\ud83d\udd39 NIST pH powders (4.01, 7.00, 10.01) \u2013 ready for calibration right out of the box<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Whether you\u2019re in R&amp;D, pharma, food &amp; beverage, or environmental testing \u2013 the Ti\u201150 gives you\u00a0<\/span><strong><span class=\"\">reproducible results, less rework, and more sleep<\/span><\/strong><span class=\"\">. \ud83d\ude34<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12348\" src=\"https:\/\/www.skzindustrial.com\/wp-content\/uploads\/2026\/04\/4.jpg\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/www.skzindustrial.com\/wp-content\/uploads\/2026\/04\/4.jpg 800w, https:\/\/www.skzindustrial.com\/wp-content\/uploads\/2026\/04\/4-768x768.jpg 768w, https:\/\/www.skzindustrial.com\/wp-content\/uploads\/2026\/04\/4-12x12.jpg 12w, https:\/\/www.skzindustrial.com\/wp-content\/uploads\/2026\/04\/4-300x300.jpg 300w, https:\/\/www.skzindustrial.com\/wp-content\/uploads\/2026\/04\/4-600x600.jpg 600w, https:\/\/www.skzindustrial.com\/wp-content\/uploads\/2026\/04\/4-100x100.jpg 100w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Let\u2019s be real \u2013 manual titration is tedious, error\u2011prone, and eats up your afternoon. \ud83d\ude29 You watch the colour change, count drops, pray your eyes don\u2019t deceive you\u2026 and then re\u2011do it all because the R\u00b2 isn\u2019t good enough. That\u2019s exactly why we built the\u00a0Ti\u201150 (641021C11)\u00a0\u2013 an\u00a0automatic potentiometric titrator\u00a0that turns hours of sweat into minutes [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-12540","post","type-post","status-publish","format-standard","hentry","category-company-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.skzindustrial.com\/zh\/wp-json\/wp\/v2\/posts\/12540","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.skzindustrial.com\/zh\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.skzindustrial.com\/zh\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.skzindustrial.com\/zh\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.skzindustrial.com\/zh\/wp-json\/wp\/v2\/comments?post=12540"}],"version-history":[{"count":1,"href":"https:\/\/www.skzindustrial.com\/zh\/wp-json\/wp\/v2\/posts\/12540\/revisions"}],"predecessor-version":[{"id":12543,"href":"https:\/\/www.skzindustrial.com\/zh\/wp-json\/wp\/v2\/posts\/12540\/revisions\/12543"}],"wp:attachment":[{"href":"https:\/\/www.skzindustrial.com\/zh\/wp-json\/wp\/v2\/media?parent=12540"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.skzindustrial.com\/zh\/wp-json\/wp\/v2\/categories?post=12540"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.skzindustrial.com\/zh\/wp-json\/wp\/v2\/tags?post=12540"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}