SKZ1043A Automatic Potentiometric Titrator

3

Product Download

If you want to download this product information Please click here

Used for the detection of index with potential capacity analysis, can be used as special instrument for the
detection of penicillin, by measuring the change in electrode potential, to measure the ion concentration,
widely used for the pharmaceutical industry, food industry, petrochemical industry, metallurgy,
environmental protection, electroplating materials industry. 
Main functions
1.Titration type of chemical reaction: acid-base titration, redox titration, complexometric titration and
precipitation titration.
2. Different titration solvent: aqueous and non-aqueous titration titration.
3.Titration different ways: chemical titration, determination of penicillin, penicillin and penicillin degradation
measurement calibration
Principle:
By measuring the change in electrode potential, to measure the ion concentration.
First, choose the appropriate indicator electrode and a reference electrode, and the test solution formed a
working battery, then add titrant. In the titration process, due to a chemical reaction, the measured ion
concentration is changing, thus indicating electrode potential changes. Near the end of the titration, ion
concentration measured mutation, causing the electrode potential jump, therefore, according to the
electrode potential to determine the titration end point, measured results
Features:
1. With LCD display, display test parameters and measurement results
2. With pre-titration, endpoint titration preset, blank titration or manual titration functions and can be used to
generate special titration according to user mode
3. Different electrode can be used: acid-base titration, redox titration, precipitation titration, complexometric
titration, and other non-aqueous titration and pH measurement
4. Mixing system using PWM modulation technology, low noise
5. There are RS-232 communication interface can be accessed TP-16, print the test data and calculation
results titration curve
6. Titration can use special software and computer communications, real-time display on the computer. In
addition, titration mode can be edited and modified for remote control operation, and the calculation of a
variety of statistical results
7. Perchloric acid titration system with anti-corrosion materials, can be a variety titration reaction
Technical parameters
Instrument level
0.001Grade
Measurement parameter
pH value,mV(ORP),Temp. value
Measure range
pH
(0.00~14.00)pH
mV
(-1800.0~1800.0)mV
Temp.
(-5.0~105.0)℃
Resolution
pH
0.01pH
mV
0.1mV
Temp.
0.1℃
Accuracy
pH
±0.01pH±1bit
mV
±0.03%FS
Temp.
±0.3℃±1bit
Buret Drive
titration repeatability
0.2%
titration Sensitivity
±2mV
titration Capacitance tolerance
10ml Buret: ±0.025ml, 20ml Buret: ±0.035
ml
Buret Resolution
10ml Buret: 1/10000, 20ml Buret: 2/10000
Burette infusion or infusion rate
(50±10)s (burette full scale)
Stability
(±0.3mV±1 bit)/3h
Power supply
AC (220±22)V, (50±1)Hz
Overall chassis number
WXS-A002-1
Dimensions (mm), weight (kg)
340×400×400, 10

 

Name
*
Mobile
*
Email
*
Content
*